Jeti Specbos 2501 UV VIS NIR spectroradiometer
JETI specbos 2501 is the evolution of the successful models specbos 1211-2 and the spectraval series. It is a fast and precise broadband spectroradiomter, which is available in three basic models: specbos 2501, specbos 2501-NIR and specbos 2501-UV. These basic models can be customized by combining with one or more add-ons (please see below).
Highlights
- Max Wavelength range 200 to 1100 nm
- Fast measurement of Radiance
- Radiometric software JETI LiVal is included in the standard scope of delivery
- Optical bandwidth 4 nm (can be increased to 2 nm by adding the HiRes add-on, only available for VIS wavelength range)
- Measurement in Radiance (basic configuration) and Irradiance mode (diffusor required)
- Start of measurement with external trigger signal by adding the trigger add-on
- Can be equipped with LAN connector incl. PoE function by adding the LAN add-on
- Highly sensitive
- Internal target spot laser
- Mechanical shutter for dark signal compensation
- Automatic measurement in selectable time intervals
- USB-C
- Bluetooth (standard, can be replaced by LAN connector, see LAN add-on)
specbos 2501 can be customised to your needs
Please add one or more of the following add-ons to configure specbos 2501 according to your requirements:
-
HiRes
Increases the optical resolution (FWHM) from 4 nm to 2 nm in VIS and 3 nm in NIR/UV -> specbos 2501-HiRes
Can be combined with specbos 2501 -
LAN
Bluetooth interface replaced by LAN interface with PoE function -> specbos 2501-LAN
Can be combined with specbos 2501, 2501-NIR, 2501-UV -
focus
Necessary, if the device is to be used with an Add-on optics -> specbos 2501-focus
Can be combined with specbos 2501, 2501-NIR, 2501-UV -
trigger
Enables the possibility of a hardware triggered measurement -> specbos 2501-trigger
Can be combined with specbos 2501, 2501-NIR, 2501-UV
|
Wavelength range |
specbos 2501 |
380 ~ 780 nm |
|
specbos 2501-NIR |
380 ~ 1100 nm |
|
|
specbos 2501-UV |
200 ~ 1100 nm |
|
|
Optical resolution (FWHM) |
≤ 4.0 nm (all versions); ≤ 2.0 nm (VIS, specbos 2501-HiRes) |
|
|
Wavelength resolution |
1.0 nm |
|
|
Digital electronic resolution |
16 bit ADC |
|
|
Viewing angle |
2.1° (Radiance mode) |
|
|
Measuring distance/ diameter |
15 cm - Ø 5 mm; 50 cm - Ø 20 mm; 100 cm – Ø 38 mm; 200 cm – Ø 74 mm (measured from front end of the device) |
|
| Measuring values |
|
Spectral Radiance, Luminance, total Radiance, x,y, u’,v’, CCT, CRI, color purity, RGB, PAR, TLCI, circadian metrics and others |
| With optional diffusor |
Spectral Irradiance/ total Irradiance/ Illuminance |
|
|
Measuring ranges/ Accuracies/ Reproducibilities |
||
|
Luminance measuring range |
0.2 ~ 150 000 cd/m² (Illuminant A) | |
|
0.2 ~ 100 000 cd/m² (typical warm white LED) |
||
|
(higher values with optional filter) |
||
|
Luminance accuracy |
± 3.5 % (Illuminant A @ 100 cd/m2, k=2) |
|
|
Luminance reproducibility |
± 1 % |
|
|
Chromaticity accuracy |
± 0.002 x, y (Illuminant A, k=2) |
|
|
Color reproducibility |
± 0.0005 x, y (Illuminant A) |
|
|
Illuminance measuring range |
1 ~ 800 000 lx (Illuminant A), 1 ~ 500 000 lx (typical warm white LED) |
|
|
Illuminance accuracy |
± 2.4 % (Illuminant A @ 2000 lx, k=2) |
|
|
CCT reproducibility |
± 20 K (Illuminant A) |
|
|
Max. wavelength error |
± 0.3 nm (HgAr line source) |
|
|
Polarization error f8 |
< 1 % | |